aaee.netResidence Time — the engineering that keeps water and air survivable
Measurement

BOD and COD

Two ways of asking how much oxygen-demanding material is in a water, why they disagree, and what the gap tells you.

Round-bottom flask heating orange liquid over a burner amid lab glassware and test tubes
Two ways of asking the same question about oxygen demand. The gap between the answers is the useful part.
Photo: Mikhail Nilov / Pexels

Two Numbers, One Question, and a Useful Argument

The question is simple: how much oxygen-demanding material is in this water? The answer depends entirely on how you ask it.

Biochemical oxygen demand — BOD — measures what microorganisms actually consume when given five days at 20 °C in the dark. The test is slow by design. You seed the sample with bacteria, seal it from the atmosphere, and measure how much dissolved oxygen disappears. Five days is the classic incubation period, long enough to capture the bulk of carbonaceous oxidation but short enough to avoid the complication of nitrification muddying the result. The number you get is usually reported as BOD₅. It reflects real biological activity: if a compound is refractory, resistant to microbial attack, the bacteria ignore it and it contributes nothing to the BOD.

Chemical oxygen demand — COD — takes a harsher approach. The sample is heated under reflux with a strong oxidising agent, typically acidified potassium dichromate, and the oxygen equivalent consumed is measured colorimetrically. The digestion takes a couple of hours rather than five days, and it doesn't care whether a compound is biodegradable. If the dichromate can oxidise it, it counts. Aromatic compounds, chlorinated solvents, many industrial organics that bacteria would struggle with — all show up in COD where they would barely register in a BOD test.

The number you get is usually reported as BOD₅.

This is why the two numbers almost always disagree, and why the gap between them carries information.

A sampling point with a hose and a labelled bottle at a works
A hose, a valve and a bottle: the start of the chain that ends as a number in a compliance table. Photo: Polina Tankilevitch / Pexels

What the Ratio Tells an Engineer

For a relatively clean domestic wastewater, with its mix of sugars, proteins and fats, the COD is typically somewhat higher than the BOD₅ — perhaps in a ratio of around 1.5 to 2. The compounds are largely biodegradable; the chemical test picks up a little more, but not dramatically so. When that ratio climbs to 3 or 4 or higher, the water contains a significant fraction of material that resists biological attack. Industrial effluents — from pharmaceutical manufacture, petrochemical processes, textile dyeing — often produce ratios like this. A high COD/BOD ratio is a warning that conventional activated-sludge treatment will struggle, and that the biological oxygen demand numbers at a works may not reflect the true loading arriving in the influent.

The ratio also works the other direction. A very low ratio — COD barely above BOD — suggests nearly everything present is readily biodegradable, which is operationally reassuring but analytically worth questioning: it may mean the COD test is incomplete, or that something is interfering with the dichromate oxidation.

There are interferences worth knowing. Chloride at high concentrations can reduce dichromate and inflate COD results. Some compounds — pyridine, for instance — resist dichromate oxidation and will be undercounted. The BOD test has its own vulnerabilities: if the seed bacteria are absent or inhibited, the result is low not because the water is clean but because nothing is eating it. Both tests, in other words, measure a process rather than a fixed composition, which is why a works is only as honest as its sampler.

COD has largely displaced BOD for process control at treatment works, simply because waiting five days for a number is impractical when something is wrong today.

COD has largely displaced BOD for process control at treatment works, simply because waiting five days for a number is impractical when something is wrong today. BOD retains its place partly as a regulatory metric — decades of discharge standards are written around it — and partly because it answers a genuinely different question: not what's there chemically, but what the receiving water body will actually lose in oxygen when this effluent arrives.

That distinction matters in rivers. The river doesn't know about dichromate; it runs on biology. COD is the faster, more reproducible figure. BOD is the one closer to what happens next.

A row of painted valve wheels and pipework at a treatment works
Most of a works is valves and levels. The process is set by deciding where water is allowed to go next. Photo: ClickerHappy / Pexels